modbus_set_indication_timeout - Man Page
set timeout between indications
Synopsis
void modbus_set_indication_timeout(modbus_t *ctx, uint32_t to_sec, uint32_t to_usec);
Description
The modbus_set_indication_timeout() function shall set the timeout interval used by a server to wait for a request from a client.
The value of to_usec argument must be in the range 0 to 999999.
If both to_sec and to_usec are zero, this timeout will not be used at all. In this case, the server will wait forever.
Return Value
The function shall return 0 if successful. Otherwise it shall return -1 and set errno.
Errors
- EINVAL
The argument ctx is NULL or to_usec is larger than 1000000.
See Also
modbus_get_indication_timeout(3) modbus_get_response_timeout(3) modbus_set_response_timeout(3)
Authors
The libmodbus documentation was written by Stéphane Raimbault <stephane.raimbault@gmail.com>
Referenced By
modbus_get_indication_timeout(3).