mge-shut - Man Page

Driver for SHUT Protocol UPS equipment

Synopsis

mge-shut -h

mge-shut -a UPS_NAME [OPTIONS]

Note

This man page only documents the hardware-specific features of the mge-shut driver​. For information about the core driver, see nutupsdrv(8)​.

Supported Hardware

mge-shut supports all recent Eaton, MGE and Dell UPS models which use the SHUT (Serial HID UPS Transfer) protocol​.

Older MGE models, such as Pulsar ESV+, Pulsar EX and Pulsar ES+, use the U-Talk protocol and should use the mge-utalk driver​.

Extra Arguments

This driver also supports the following optional settings:

lowbatt=num

Set the low battery warning threshold at which shutdown is initiated by upsmon(8)​.

The factory default value is 30 (in percent), and can be settable depending on the exact model​.

offdelay=num

Set the timer before the UPS is turned off after the kill power command is sent (via the -k switch)​.

The default value is 20 (in seconds)​. Usually this must be lower than ondelay, but the driver will not warn you upon startup if it isn’t​.

ondelay=num

Set the timer for the UPS to switch on in case the power returns after the kill power command had been sent but before the actual switch off​. This ensures the machines connected to the UPS are, in all cases, rebooted after a power failure​.

The default value is 30 (in seconds)​. Usually this must be greater than offdelay, but the driver will not warn you upon startup if it isn’t​. Some UPSes will restart no matter what, even if the power is (still) out at the moment this timer elapses​. In that case, you could try if setting ondelay = -1 in ups​.conf helps​.

Warning
The ondelay parameter was set in ten-seconds unit in the legacy mge-shut(8) driver (e​.g​. 3 for 30 seconds)​. It is now set in seconds (30 for 30 seconds)​. Make sure you use the correct unit in your configuration​.

notification=num

Set notification type to 1 (no), 2 (light) or 3 (yes)​.

This argument is ignored​. It is only here for backward compatibility​.

Known Issues

Repetitive timeout and staleness

Some models tend to be unresponsive with the default polling frequency​. The result is that you have some "data stale" errors in your system log​.

In this case, simply modify the general parameter pollinterval to a higher value (like 10 for 10 seconds)​. This should solve the issue​.

Using notification=3 might also help​.

Author

Arnaud Quette

See Also

The core driver

nutupsdrv(8)

Internet resources

The NUT (Network UPS Tools) home page: https://www​.networkupstools​.org/historic/v2​.8​.5/

Referenced By

mge-utalk(8), nut(7), nutupsdrv(8), upsd(8).