sd_bus_add_object_manager - Man Page

Add a D-Bus object manager for a D-Bus object sub-tree

Synopsis

#include <systemd/sd-bus​.h>

int sd_bus_add_object_manager(sd_bus *bus, sd_bus_slot **slot, const char *path);

Description

sd_bus_add_object_manager() installs a handler for the given path that implements the GetManagedObjects() method of the org​.freedesktop​.DBus​.ObjectManager interface​. See org​.freedesktop​.DBus​.ObjectManager​[1] for more information​.

To implement the InterfacesAdded and InterfacesRemoved signals of the org​.freedesktop​.DBus​.ObjectManager interface, call sd_bus_emit_interfaces_added(3) and sd_bus_emit_interfaces_removed(3) whenever interfaces are added or removed from the sub-tree, respectively​.

When sd_bus_add_object_manager() succeeds, a slot is created internally​. If the output parameter slot is NULL, a "floating" slot object is created, see sd_bus_slot_set_floating(3)​. Otherwise, a pointer to the slot object is returned​. In that case, the reference to the slot object should be dropped when the object manager is not needed anymore, see sd_bus_slot_unref(3)​.

Return Value

On success, sd_bus_add_object_manager() returns a non-negative integer​. On failure, it returns a negative errno-style error code​.

Errors

Returned errors may indicate the following problems:

-EINVAL

One of the required parameters is NULL or path is not a valid object path​.

-ENOPKG

The bus cannot be resolved​.

-ECHILD

The bus was created in a different process, library or module instance​.

-ENOMEM

Memory allocation failed​.

Notes

Functions described here are available as a shared library, which can be compiled against and linked to with the libsystemd ​pkg-config(1) file​.

All functions listed here are thread-agnostic and only a single thread may operate on a given object at any given time​. Different threads may access the same object at different times​. Multiple independent objects may be used from different threads in parallel​.

The code described here uses getenv(3), which is declared to be not multi-thread-safe​. This means that the code calling the functions described here must not call setenv(3) from a parallel thread​. It is recommended to only do calls to setenv() from an early phase of the program when no other threads have been started​.

History

sd_bus_add_object_manager() was added in version 221​.

See Also

sd-bus(3), busctl(1), sd_bus_add_object_vtable(3), sd_bus_emit_interfaces_added(3), sd_bus_slot_unref(3)

Notes

1.

org.freedesktop.DBus.ObjectManager
https://dbus.freedesktop.org/doc/dbus-specification.html#standard-interfaces-objectmanager

Info