create a new EGL sync object

C Specification

EGLSync eglCreateSync(EGLDisplay display, EGLEnum type, EGLAttrib const * attrib_list);

Parameters

display

Specifies the EGL display connection​.

type

Specifies the type of sync object to create​.

attrib_list

Specifies attributes and attribute values for the sync object being created​.

Description

sync objects are provided to enable synchronization of client API operations between threads and/or between API contexts​. Sync objects may be tested or waited upon by application threads​.

Sync objects have a status with two possible states: signaled and unsignaled​. Initially, sync objects are unsignaled​. EGL may be asked to wait for a sync object to become signaled, or a sync object's status may be queried​.

Depending on the type of a sync object, its status may be changed either by an external event, or by explicitly signaling and unsignaling the sync​.

eglCreateSync creates a sync object of the specified type associated with the specified display display, and returns a handle to the new object​. attrib_list is an attribute-value list specifying other attributes of the sync object, terminated by an attribute entry EGL_NONE​. Attributes not specified in the list will be assigned their default values​.

Once the condition of the sync object is satisfied, the sync is signaled, causing any eglClientWaitSync or eglWaitSync commands blocking on sync to unblock​.

Creating Fence Sync Objects

If type is EGL_SYNC_FENCE, a fence sync object is created​. In this case attrib_list must be NULL or empty (containing only EGL_NONE)​. Attributes of the fence sync object, and their initial values, are:

EGL_SYNC_TYPE

EGL_SYNC_FENCE

EGL_SYNC_STATUS

EGL_UNSIGNALED

EGL_SYNC_CONDITION

EGL_SYNC_PRIOR_COMMANDS_COMPLETE

When a fence sync object is created, eglCreateSync also inserts a fence command into the command stream of the bound client API's current context (i​.e​., the context returned by eglGetCurrentContext), and associates it with the newly created sync object​.

The only condition supported for fence sync objects is EGL_SYNC_PRIOR_COMMANDS_COMPLETE, which is satisfied by completion of the fence command corresponding to the sync object, and all preceding commands in the associated client API context's command stream​. The sync object will not be signaled until all effects from these commands on the client API's internal and framebuffer state are fully realized​. No other state is affected by execution of the fence command​.

Creation of fence sync objects requires support from the bound client API, and will not succeed unless the client API satisfies one of the following properties​. Note that eglWaitSync also requires satisfying these conditions​.

Creating Opencl Event Sync Objects

If type is EGL_SYNC_CL_EVENT, an OpenCL event sync object is created​. In this case attrib_list must contain the attribute EGL_CL_EVENT_HANDLE, set to a valid OpenCL event handle returned by a call to clEnqueueReleaseGLObjects or clEnqueueReleaseEGLObjects; other types of OpenCL event handles are not supported​. Note that EGL_CL_EVENT_HANDLE is not a queriable property of a sync object​. Attributes of the OpenCL event sync object, and their initial values, are:

EGL_SYNC_TYPE

EGL_SYNC_CL_EVENT

EGL_SYNC_STATUS

Depends on status of event

EGL_SYNC_CONDITION

EGL_SYNC_CL_EVENT_COMPLETE

The status of such a sync object depends on event​. When the status of event is CL_QUEUED, CL_SUBMITTED, or CL_RUNNING, the status of the linked sync object will be EGL_UNSIGNALED​. When the status of event changes to CL_COMPLETE, the status of the linked sync object will become EGL_SIGNALED​.

The only condition supported for OpenCL event sync objects is EGL_SYNC_CL_EVENT_COMPLETE, which is satisfied when the status of the OpenCL event associated with the sync object changes to CL_COMPLETE​.

Creating a linked sync object places a reference on the linked OpenCL event object​. When the sync object is deleted, the reference will be removed from the event object​.

However, implementations are not required to validate the OpenCL event, and passing an invalid event handle in attrib_list may result in undefined behavior up to and including program termination​.

Notes

eglCreateSync is supported only if the EGL version is 1​.5 or greater​.

Errors

eglCreateSync returns EGL_NO_SYNC on failure​.

If display is not the name of a valid, initialized EGLDisplay, an EGL_BAD_DISPLAY error is generated​.

If attrib_list contains an attribute name not defined for the type of sync object being created, an EGL_BAD_ATTRIBUTE error is generated​.

If type is not a supported type of sync object, an EGL_BAD_PARAMETER error is generated​.

If type is EGL_SYNC_FENCE and no context is current for the bound API (i​.e​., eglGetCurrentContext returns EGL_NO_CONTEXT), an EGL_BAD_MATCH error is generated​.

If type is EGL_SYNC_FENCE and display does not match the EGLDisplay of the currently bound context for the currently bound client API (the EGLDisplay returned by eglGetCurrentDisplay), an EGL_BAD_MATCH error is generated​.

If type is EGL_SYNC_FENCE and the current context for the currently bound client API does not support fence commands, an EGL_BAD_MATCH error is generated​.

If type is EGL_SYNC_CL_EVENT and EGL_CL_EVENT_HANDLE is not specified in attrib_list, or its attribute value is not a valid OpenCL event handle as described above, then an EGL_BAD_ATTRIBUTE error is generated​.